Skip to main content
Quality control guide

AQL chart: sample sizes, inspection levels and accept/reject numbers

An AQL chart tells an inspector how many units to pull from a lot and how many defects are allowed before the lot fails. You read it in two steps: the lot size and inspection level give a sample size code letter, and that letter plus the AQL you chose gives the sample size and the accept and reject numbers.

The tables below are the single-sampling, normal-inspection tables of MIL-STD-105D, the US military standard that ANSI/ASQ Z1.4 and ISO 2859-1 grew out of. ASTM notes that the basic sampling tables remain the same across these standards, with minor differences between editions, so check the edition named in your inspection contract.

Quick answer

Example: 3,000 units at General Level II means code K, a sample of 125, and at AQL 2.5 the lot passes with 7 defects or fewer.

Lot size 1,201 to 3,200 at General Inspection Level II gives code letter K. Code K means a sample of 125 units. At AQL 2.5 the lot is accepted with up to 7 defective units and rejected at 8; at AQL 4.0 it is accepted with up to 10 and rejected at 11.

Key takeaways: agree the inspection level, the AQL for each defect class and the standard edition with the supplier before production, and write them into the purchase order.

How to read an AQL chart

Single sampling, normal inspection.

Step 1

Find the lot size row and the inspection level column: that gives a code letter.

Step 2

The code letter gives the sample size, such as K = 125 units.

Step 3

Under your AQL, read Ac (accept if defects are at or below) and Re (reject if at or above).

Default level

MIL-STD-105D: "Unless otherwise specified, Inspection Level II will be used."

Best for

  • Buyers ordering a production run from a Chinese factory who need a pass or fail rule for the lot
  • Small brands writing their first inspection requirements into a purchase order

Not best for

  • Treating AQL 2.5 as "2.5% defects allowed in the shipment", when it is a sampling limit for the process average
  • Choosing a special level such as S-1 for a large order to save time, which raises the sampling risk

What to prepare

  • Lot size per product and the inspection level (General Level II unless you choose otherwise)
  • The AQL for each defect class, for example critical, major and minor

Proof examples

  • The lot size used is the real lot, not the whole order split across several products
  • Each defect class has its own AQL, and critical defects are defined
Table 1

Sample size code letters by lot size and inspection level

From MIL-STD-105D Table I. General Levels I, II and III; special levels S-1 to S-4 are for small samples where larger sampling risk is acceptable.

Lot size S-1S-2S-3S-4IIIIII
2 to 8 AAAAAAB
9 to 15 AAAAABC
16 to 25 AABBBCD
26 to 50 ABBCCDE
51 to 90 BBCCCEF
91 to 150 BBCDDFG
151 to 280 BCDEEGH
281 to 500 BCDEFHJ
501 to 1,200 CCEFGJK
1,201 to 3,200 CDEGHKL
3,201 to 10,000 CDFGJLM
10,001 to 35,000 CDFHKMN
35,001 to 150,000 DEGJLNP
150,001 to 500,000 DEGJMPQ
500,001 and over DEHKNQR
Table 2

Sample size for each code letter

From MIL-STD-105D Table II-A, single sampling, normal inspection. There is no letter I or O.

Code letter Sample size (units)
A 2
B 3
C 5
D 8
E 13
F 20
G 32
H 50
J 80
K 125
L 200
M 315
N 500
P 800
Q 1,250
R 2,000
Table 3

Accept / reject numbers by AQL (Ac/Re)

From MIL-STD-105D Table II-A, single sampling, normal inspection. Where the standard points to another row with an arrow, the cell shows that row's sample size; inspect that many units instead. If the sample is as large as the lot, inspect every unit.

Code (sample) AQL 0.65AQL 1.0AQL 1.5AQL 2.5AQL 4.0AQL 6.5
D (8) 0/1, sample 200/1, sample 130/10/1, sample 51/2, sample 131/2
E (13) 0/1, sample 200/10/1, sample 81/2, sample 201/22/3
F (20) 0/10/1, sample 131/2, sample 321/22/33/4
G (32) 0/1, sample 201/2, sample 501/22/33/45/6
H (50) 1/2, sample 801/22/33/45/67/8
J (80) 1/22/33/45/67/810/11
K (125) 2/33/45/67/810/1114/15
L (200) 3/45/67/810/1114/1521/22
M (315) 5/67/810/1114/1521/2221/22, sample 200
N (500) 7/810/1114/1521/2221/22, sample 31521/22, sample 200
Who this helps

Use an AQL plan when a lot is too large to check every unit.

AQL sampling decides whether a whole production lot passes from a sample. It does not promise zero defects: MIL-STD-105D says an AQL does not give the supplier the right to knowingly supply any defective unit.

Best for 01

Buyers ordering a production run from a Chinese factory who need a pass or fail rule for the lot

Best for 02

Small brands writing their first inspection requirements into a purchase order

Best for 03

Buyers comparing inspection quotes that use different levels or AQL values

Before purchasing

What to agree with the supplier before an AQL inspection

Set these in the purchase order, so the inspector and the factory work from the same plan.

Quote inputs · 4 items

What an inspector needs

  • Lot size per product and the inspection level (General Level II unless you choose otherwise)
  • The AQL for each defect class, for example critical, major and minor
  • A defect list with photos or a golden sample, and the measurements to check
  • The standard and edition to follow: ANSI/ASQ Z1.4 or ISO 2859-1
Control checks · 4 items

AQL plan checks

  • The lot size used is the real lot, not the whole order split across several products
  • Each defect class has its own AQL, and critical defects are defined
  • The inspector draws the sample at random from the finished, packed goods
  • The report states the sample size, defects found by class, and the Ac/Re used
Risk flags · 4 items

AQL mistakes

  • Treating AQL 2.5 as "2.5% defects allowed in the shipment", when it is a sampling limit for the process average
  • Choosing a special level such as S-1 for a large order to save time, which raises the sampling risk
  • Leaving defect classes undefined, so the factory and the inspector argue about what counts as major
  • Booking the inspection before production is finished, when the lot is not yet complete
Workflow notes

Choosing the level and the AQL

Route note 01 Guidance

General Level II is the default in the standard; Level I samples less and Level III samples more for the same lot.

Route note 02 Guidance

Special levels S-1 to S-4 are for cases where small samples are necessary and larger sampling risks can be tolerated, such as destructive tests.

Route note 03 Guidance

The standard does not set which AQL to use for each defect class. The buyer chooses it, and many buyers allow no critical defects at all.

Route note 04 Guidance

JTLGO's own checks are photo, quantity, label and packaging checks when goods reach its warehouse in China. For AQL sampling at the factory, book a third-party inspection company and give it the plan from this page.

Reference sources: MIL-STD-105D sampling procedures and tables (Public.Resource.Org copy) · ASQ quality glossary: acceptance quality limit · ISO 2859-1:2026 (standard page) · ASTM: preservation of the military standards for acceptance sampling

FAQ

AQL questions buyers ask

What does AQL mean?

AQL stands for acceptance quality limit, originally acceptable quality level. ASQ defines it as the quality level that, in a continuing series of lots and for the purpose of sampling inspection, is the limit of a satisfactory process average. It sets the pass or fail numbers for a sample, not a promise about every unit.

How do I read an AQL chart?

Find your lot size in Table 1 and read across to the inspection level, usually General Level II, to get a code letter. Table 2 turns that letter into a sample size. In Table 3, the cell under your AQL gives Ac/Re: accept the lot if defects found are at or below Ac, reject it at Re or above.

What are AQL inspection levels?

There are three general levels, I, II and III, and four special levels, S-1 to S-4. MIL-STD-105D makes Level II the default, uses Level I where less discrimination is needed and Level III where more is needed. The special levels give small samples for cases where larger sampling risk can be tolerated.

Is the MIL-STD-105 table the same as ANSI Z1.4 and ISO 2859-1?

Essentially, yes. ASTM notes that the basic sampling tables remain the same in ANSI/ASQ Z1.4 and ISO 2859-1 as in MIL-STD-105D and E, with some changes between editions. ISO 2859-1 was revised in 2026, so name the edition you want in the contract and check a few cells against it.

What is the difference between an AQL inspection and a factory audit?

An AQL inspection checks a sample of finished goods from one production lot and passes or fails that lot. A factory audit looks at the supplier itself: its legal registration, production capacity, quality system and working conditions. Buyers usually audit before the first order and inspect lots before each shipment.

Does JTLGO carry out AQL inspections?

JTLGO checks goods when they reach its warehouse in China, with photos, quantity, label and packaging checks before consolidation and shipping. For AQL sampling at the factory before goods leave, book a third-party inspection company and give it your lot size, level, AQL values and defect list.